Logo
 
Standard Arama
Standard Arama Sisteme Giriş
Standard Detayı
TÜRK STANDARDI
TS No : TS EN ISO 12846      
Kabul Tarihi : 5.06.2012
Hazırlık Grubu : Teknik Kurul
Doküman Tipi :
Yürürlük Durumu : U (Yürürlükteki Standard/Standard)
Başlık : Su kalitesi - Cıva tayini - Zengilleştirilmiş ve zengilleştirilmemiş atomik absorpsiyon spektrometre (aas) kullanma metodu
Başlık (İng) : Water quality - Determination of mercury - Method using atomic absorption spectrometry (AAS) with and without enrichment
Kapsam :
Kapsam (İng) : ISO 12846:2012 specifies two methods for the determination of mercury in drinking, surface, ground, rain and waste water after appropriate pre-digestion. For the first method, an enrichment step by amalgamation of the Hg on, for example, a gold/platinum adsorber is used. For the second method, the enrichment step is omitted. The choice of method depends on the equipment available, the matrix and the concentration range of interest. Both methods are suitable for the determination of mercury in water. The method with enrichment commonly has a practical working range from 0,01 µg/l to 1 µg/l. The mean limit of quantification (LOQ) reported by the participants of the validation trial was 0,008 µg/l. This information on the LOQ gives the user of ISO 12846:2012 an orientation and does not replace the estimation of performance data from laboratory specific data. It has to be considered that it is possible to achieve lower LOQs with specific instrumentation (e.g. single mercury analysers). The method without enrichment commonly has a practical working range starting at 0,05 µg/l. The LOQ reported by the participants of the validation trial was 0,024 µg/l. It is up to the user, based on the specific application, to decide whether higher concentrations are determined by omitting the enrichment step and/or by diluting the sample(s). The sensitivity of both methods is dependent on the selected operating conditions. Another possibility for the determination of extremely low Hg concentrations down to 0,002 µg/l without pre-concentration is the application of atomic fluorescence spectrometry (see ISO 17852). Specific atomic-absorption mercury analysers allow determinations down to 0,010 µg/l without pre-concentration. In general, the determination of trace concentrations of Hg by AAS (or AFS) is dependent on clean operating conditions in the laboratory and on the use of high-purity chemicals with negligible low-Hg blanks. Note that ISO 12846:2012 may be applied to industrial and municipal waste water after an additional digestion step performed under appropriate conditions and after suitable method validation. A potential sample stability issue (mercury loss) for anaerobic reducing industrial effluents has to be considered thoroughly.
Yerini Aldığı : TS EN 1483 :2008;  TS EN 12338 :1999;  
Yararlanılan Kaynak : EN ISO 12846:2012
Uluslararası Karşılıklar : ISO 12846-EQV; EN ISO 12846-EQV
ICS Kodu : 13.060.50 Suyun Kimyasal Maddeler İçin İncelenmesi
Cen/Cenelec : CEN/ISO
Dili : en
Renk Durumu : Siyah-Beyaz
Uygulama Durumu : Yürürlükte
Sayfa Sayısı : 24
Fiyatı : 64,00 EURO  (2.237,57 TL + %10 Kdv)
Çakışan Standart Varsa İptal Tarihi (DOW)-