Logo
 
Standard Arama
Standard Arama Sisteme Giriş
Standard Detayı
TÜRK STANDARDI
TS No : TS HD 60269-2/A1      
Kabul Tarihi : 8.12.2022
Hazırlık Grubu : Teknik Kurul
Doküman Tipi :
Yürürlük Durumu : U (Yürürlükteki Standard/Standard)
Başlık : Alçak gerilim sigortaları - Bölüm 2: Yetkili kişiler tarafından kullanılması amaçlanan sigortalarla ilgili tamamlayıcı gereklilikler (esas olarak endüstriyel uygulamalar için kullanılan sigortalar) - Standart hale getirilmiş A ila K sigorta sistemleriyle ilgili örnekler
Başlık (İng) : Low-voltage fuses - Part 2: Supplementary requirements for fuses for use by authorized persons (fuses mainly for industrial application) - Examples of standardized systems of fuses A to K
Kapsam :
Kapsam (İng) : IEC 60269-2:2013 provides supplementary requirements for fuses for use by authorized persons and are generally designed to be used in installations where the fuse-links are accessible to, and may be replaced by, authorized persons only. Fuses for use by authorized persons according to the following fuse systems also comply with the requirements of the corresponding subclauses of IEC 60269-1, unless otherwise defined in this standard. This standard is divided into fuse systems, each dealing with a specific example of standardized fuses for use by authorized persons: - Fuse system A: Fuses with fuse-links with blade contacts (NH fuse system), - Fuse system B: Fuses with striker fuse-links with blade contacts (NH fuse system), - Fuse system C: Fuse-rails (NH fuse system), - Fuse system D: Fuse-bases for busbar mounting (NH fuse system), - Fuse system E: Fuses with fuse-links for bolted connections (BS bolted fuse system), - Fuse system F: Fuses with fuse-links having cylindrical contact caps (NF cylindrical fuse system), - Fuse system G: Fuses with fuse-links with offset blade contacts (BS clip-in fuse system), - Fuse system H: Fuses with fuse-links having 'gD' and 'gN' characteristic (class J and class time delay and non time delay fuse types), - Fuse system I: gU fuse-links with wedge tightening contacts, - Fuse system J: Fuses with fuse-links having 'gD class CC' and 'gN class CC' characteristics (class CC time delay and non-time delay fuse types), - Fuse system K: gK fuse-links with blade for bolted connections - High fuse-link ratings from 1 250 A up to 4 800 A (master fuse-links). This fifth edition of IEC 60269-2 cancels and replaces the fourth edition published in 2010. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: 1. fuse systems A and B: modified values for the power dissipation of NH aM fuse-links; 2. fuse systems A and B: introduction of dimension r for NH fuse-links; 3. addition of new fuse system K: gK fuse-links with contacts for bolted connections. Key Words: fuse systems A to K, requirements for fuses
Tadil Edilen : TS HD 60269-2 :2014;  TS HD 60269-2 :2014;  
Yararlanılan Kaynak : HD 60269-2:2013/A1:2022
Uluslararası Karşılıklar : HD 60269-2:2013/A1-EQV; IEC 60269-2:2013/A1-EQV
ICS Kodu : 29.120.50 Sigortalar ve Diğer Aşırı Akımdan Korunma Düzenleri
Cen/Cenelec : CENELEC/IEC
Dili : en
Renk Durumu : Siyah-Beyaz
Uygulama Durumu : Yürürlükte
Sayfa Sayısı : 17
Fiyatı : 10,00 EURO  (346,70 TL + %10 Kdv)
Çakışan Standart Varsa İptal Tarihi (DOW)-