Logo
 
Standard Arama
Standard Arama Sisteme Giriş
Standard Detayı
TÜRK STANDARDI
TS No : TS EN 1504-9      
Kabul Tarihi : 19.01.2010
Hazırlık Grubu : Teknik Kurul
Doküman Tipi :
Yürürlük Durumu : U (Yürürlükteki Standard/Standard)
Başlık : Beton yapıların korunması ve tamiri için mamuller ve sistemler - Tarifler, gerekler, kalite kontrol ve uygunluk değerlendirmesi - Bölüm 9:Ürünlerin ve sistemlerin kullanımı için genel prensipler
Başlık (İng) : Products and systems for the protection and repair of concrete structures - Definitions, requirements, quality control and evaluation of conformity - Part 9: General principles for the use of products and systems
Kapsam :
Kapsam (İng) : This Part of EN 1504 sets out basic considerations for specification of protection and repair of reinforced and unreinforced concrete structures (including, for example, pavements, runways, floor slabs and pre-stressed structures) using products and systems specified in other Parts of the EN 1504 series or any other relevant European Standard or European Technical Approval. This European Standard covers atmospherically exposed, buried and submerged structures. This European Standard includes: a) the need for inspection, testing and assessment before and after repair; b) protection from causes of defects and their repair in concrete structures. Causes of such defects may include: 1) mechanical actions, e.g. impact, overloading, movement caused by settlement, blast, vibration and seismic actions; 2) chemical and biological actions from environments, e.g. sulphate attack, alkali aggregate reaction; 3) physical actions, e.g. freeze-thaw, thermal cracking, moisture movement, salt crystallisation and erosion; 4) fire damage; 5) reinforcement corrosion resulting from: i) physical loss of the protective concrete cover; ii) chemical loss of alkalinity in the protective concrete cover as a result of reaction with atmospheric carbon dioxide (carbonation); iii) chloride (or other chemical) contamination of the concrete; iv) stray electrical currents conducted or induced in the reinforcement from neighbouring electrical installations. c) repair of defects caused by inadequate design, specification or construction or use of unsuitable construction materials; d) providing the required structural capacity by: 1) replacement or addition of embedded or external reinforcement; 2) filling of cracks and voids within or between elements to ensure structural continuity; 3) replacement or addition of concrete or whole elements; e) waterproofing as an integral part of protection and repair; [...].
Yararlanılan Kaynak : EN 1504-9:2008
Uluslararası Karşılıklar : EN 1504-9-EQV
ICS Kodu : 01.040.91 Yapı Malzemeleri ve Yapılar (Terimler); 91.080.40 Beton Yapılar
Cen/Cenelec : CEN
Dili : en
Renk Durumu : Siyah-Beyaz
Uygulama Durumu : Yürürlükte
Sayfa Sayısı : 31
Fiyatı : 72,00 EURO  (2.496,22 TL + %10 Kdv)
Çakışan Standart Varsa İptal Tarihi (DOW)-